More info
Description / Abstract:
Purpose. To determine if the total coolant
flow, flow to the radiator, flow to the heater, and flow balance in
engines, meets the design intent under various thermostat opening
conditions. To provide additional data for 1D system modeling and
the model validation. In particular, the pressure drop vs. flow
characteristics for system components is required. To ensure surge
tank function under dynamic conditions, such as maximum engine
speed. To determine the necessity for a second degassing line.
To determine coolant flow for "Low Temperature Cooling Loops"
which can be either dependent or independent cooling circuits.
Coolant flow to low temperature radiator, pumps, air separators,
liquid cooled charge air cooler, and power electronics.
Applicability. All liquid cooled circuits.
Conventional engine cooling loop, System 1.
Power Electronics or Energy Storage System (Hybrid) cooling
loop. System 2.
Inter-cooler (liquid-to-air charge air cooler (CAC)) cooling
loop. System 3.
Remarks. This is a vehicle coolant flow test
procedure used for coolant system development.