5.34Cappuccino machines with milk reservoirs
5.34.1 Except as noted in 5.34.2, milk reservoirs and all milk-conveying components on cappuccino machines shall conform to the temperature performance criteria of NSF/ANSI 18.
5.34.2 The requirements in 5.34.1 shall not apply to tubing used to convey milk, provided the tubing is:
-designed such that it is completely drained of milk between uses;
-transparent enough to verify that it is void of milk; and
- no greater than 18 in (46 cm) in length.
5.34.3 Milk reservoirs and all milk conveying components, including tubing, shall conform to 5.1.3.